Phone+44(0) 20 8867 3500     sales@electropatent.co.uk

Dual Track Tap-Offs

The standard tap off unit comprises a 32A or 40 Amp unfused plug fitted

Multipoint Powerfloor Dual Track Tap Offs

A wide variety of tap-off lengths and types available to connect into the floor track. The standard tap off units are offered as 32A or 40 Amps with an unfused Multipoint Powerfloor plug. The standard tap-offs are available in two standard formats:

The standard tap-offs are available in two standard formats:

  • Tap-offs with Galvanised flexible steel conduit – with options for PVC and LFH/LSOH covering
  • Tap-offs with braided cable option CY/SY.

We can offer other cable options with bespoke solutions which are available on request – please call for advice.

Multipoint Powerfloor Tap-Offs

  • Tap offs available as 32A or 40 Amp unfused
  • Standard Flexible steel conduit version
  • Or CY/SY multi-core cable braided cable
  • Tri-rated Multi-strand cables for greater flexibility
  • Tri-rated Multi-strand cables for greater flexibility
  • However we can offer lengths from 0.5m to 20m or more depending on requirement and performance rating

Multipoint Powerfloor Tap-Offs

  • Tap offs available as 32A or 40 Amp unfused
  • Standard Flexible steel conduit version
  • Or CY/SY multi-core cable braided cable
  • Tri-rated Multi-strand cables for greater flexibility
  • Tri-rated Multi-strand cables for greater flexibility
  • However we can offer lengths from 0.5m to 20m or more depending on requirement and performance rating

Configurations:
Choice of six socket colours

White Red Blue Yellow Green Black

  • 3-wire or 4-wire tap-offs
  • 3 Earth configurations, Standard, Clean Earth or Dual Earth
  • 3x Pin styles for physical discrimination
  • Standard, non standard D-Pin & Keyed Pin

Multipoint Powerfloor Tap-Offs With Other Connectors Features

  • Fully ASTA licensed
  • Solid build with robust fabricated box section
  • Complies with the requirements of B.S. 7671, IEC60309…..
  • Flexible Pigtail/interlink can be any length, Standard pigtails normally supplied as 2.3m long
  • Superior quality conduit & fittings for better quality tap-offs Fitted with flexible steel conduit or CY/SY cable
  • Range of accessories and bespoke additions
  • All tap-offs supplied with M20 Adaptor locknut & washer

Multipoint Powerfloor Tap-Offs With Other Connectors Features

  • Fully ASTA licensed
  • Solid build with robust fabricated box section
  • Complies with the requirements of B.S. 7671, IEC60309…..
  • Flexible Pigtail/interlink can be any length, Standard pigtails normally supplied as 2.3m long
  • Superior quality conduit & fittings for better quality tap-offs Fitted with flexible steel conduit or CY/SY cable
  • Range of accessories and bespoke additions
  • All tap-offs supplied with M20 Adaptor locknut & washer

Tap offs with keyed and non standard plugs are offered where physical discrimination of a system is required. Usually standard and UPS supplies. This ensures that the correct tap off is fitted to the power supply.

Electropatent tap-offs can be supplied with 40 Amp rating with 6mm sq. cables, without the need for fuses in the plugs. Hence no need for fuses under the raised floor, which is generally considered bad practice.

Tap offs with keyed plugs are offered where physical discrimination of a system is required. This ensures that the correct tap off is fitted to the power supply.

3.0m rule for tap-off

Electropatent 40 Amp track is provided with 40 Amp rated tap-offs with 6mm cables therefore NO fusing is necessary as there is NO down rating of the current carrying capacity

Hence, where lengths longer than 3m are required, unfused tap off can be used without length restriction

If fused tap-off are required, we can supply these, however using fused tap-offs under the raised floor is bad practice and should be avoided wherever possible, as fuse replacement means having to lift the floor tiles and floor finish and more than likely moving furniture as well – so would be considered poor choice for the client / end user

Gallery

Related Products

Dual Track Main Connection Module
Dual Track Main Connection Module

Dual Track Main Connection Module

Dual Track Main Connection Modules (MCM) essentially the same as the single-track

Read More
Dual Track Extension Modules
Dual Track Extension Modules

Dual Track Extension Modules

Dual Extension Modules (EM) are essentially, as the name suggests

Read More
Dual Track Tap-Offs
Dual Track Tap-Offs

Dual Track Tap-Offs

The standard tap off unit comprises a 32A or 40 Amp unfused plug fitted

Read More

Please call us on +44 (0) 20 8867 3500 for any products or enquiries.